• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Hazard Switch Signal | 2 | 2 | 2 | -- |
Hazard Lamp Control | 1 | 1 | 1 | -- |
Turn Signal Lamp Control | B0527 00 or B0532 00 | B0528 00 or B0533 00 | B0528 00 or B0533 00 | -- |
Turn Signal/Multifunction Swtich Ground | -- | 3 | -- | -- |
Hazard Lamps Ground | -- | 1 | -- | -- |
1. Hazard Lamps Malfunction 2. Hazard Switch Malfunction 3. Turn Signal/Switch Malfunction |
The hazard flashers may be activated in any power mode. The hazard switch is permanently grounded through G106. When the hazard switch is placed in the ON position, ground is applied through the hazard switch signal circuit to the body control module (BCM). The BCM supplies battery voltage to all four turn signal lamps in an ON and OFF duty cycle. When the hazard switch is activated, the BCM sends a message to the instrument panel cluster (IPC) requesting both turn signal indicators to be cycled ON and OFF.
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
Ignition ON, observe the scan tool Hazard Lamp Switch parameter while operating the hazard switch ON and OFF. The reading should change between Active and Inactive.
⇒ | If the readings do not change, refer to Hazard Lamp Switch Malfunction. |
⇒ | If the readings do change, but the lamps do not flash ON and OFF, refer to Turn Signal Lamps and/or Indicators Malfunction. |
⇒ | If the test lamp does not illuminate, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal C for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, programming, and setup |