Warning: Refer to Fuel and Evaporative Emission Pipe Warning in the Preface section.
Warning: Refer to Gasoline/Gasoline Vapors Warning in the Preface section.
Caution: Refer to Fuel and Evaporative Emission Hose/Pipe Connection Cleaning Caution in the Preface section.
8.1. | Disconnect the EVAP canister vent solenoid valve quick connect from the EVAP canister. Refer to Plastic Collar Quick Connect Fitting Service. |
8.2. | Disengage the bracket retaining tab and remove the EVAP canister vent solenoid valve. |
1.1. | Engage the bracket retaining tab and install the EVAP canister vent solenoid valve. |
1.2. | Connect the EVAP canister vent solenoid valve quick connect to the EVAP canister. Refer to Plastic Collar Quick Connect Fitting Service. |
Caution: Refer to Fastener Caution in the Preface section.
Tighten
Tighten the bolt to 25 N·m (18 lb ft).