• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
B+ | B1492, P0622* | B1492, P0622* | -- | -- |
Field Duty Cycle Signal | B1492, P0622* | B1492, P0622* | P0622* | -- |
Turn On Signal | B1487 | -- | B1488 | -- |
* 3.7L (LLR) engine only |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Engine Running Parameter Normal Range: 5% to 99% | |||
B+ | 0% | 0% | -- |
Field Duty Cycle Signal | 0% | 0% | 99% |
The generator battery control module (GBCM) and the engine control module (ECM) monitor the generator through the generator field duty cycle signal circuit. The signal is a pulse width modulation (PWM) signal of 128 Hz. Normal duty cycle is 5-99 percent.
• | The engine is running. |
• | The engine speed is less than 1,000 RPM. |
• | DTC B1487 and DTC B1488 are not set. |
The generator field duty cycle signal is less than 5 percent duty cycle for 2 minutes.
• | The charge indicator turns ON. |
• | The driver information center (DIC) displays the SERVICE CHARGSYS message. |
• | The generator field duty cycle signal is greater than 5 percent duty cycle. |
• | The charge indicator and SERVICE CHARGSYS message will remain ON until the ignition switch is cycled after the DTC is cleared. |
Starting and Charging Schematics
Charging System Description and Operation
Control Module References for scan tool information
⇒ | If greater than the specified range, refer to ECM Signal Circuit Malfunction. |
⇒ | If less than the specified range, refer to ECM Signal Circuit Malfunction. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
⇒ | If greater than the specified range, test the signal circuit terminal 2 X1 for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, replace the GBCM. |
⇒ | If less than the specified range, replace the GBCM. |
⇒ | If greater than the specified range, test the signal circuit terminal B for a short to voltage. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM or GBCM replacement, setup, and programming. |