The efficient operation and life of the air conditioning system is dependent upon the chemical stability of the refrigeration system. When foreign materials, such as dirt, air, or moisture, contaminate the refrigeration system, they will change the stability of the refrigerant and the polyalkaline glycol (PAG) compressor oil. They will also affect the pressure-temperature relationship, reduce efficient operation, and can possibly cause interior corrosion and abnormal wear of moving parts.
Observe the following practices to ensure chemical stability in the system:
• | Wipe away dirt or oil at and near any connection before opening that connection. This will reduce the chance of dirt entering the system. |
• | Cap, plug, or tape both sides of a connection as soon as possible after opening the connection. This will prevent the entry of dirt, foreign material, and moisture. |
• | Keep all tools clean and dry, including the manifold gage set and all replacement parts. |
• | Use a clean and dry transfer device and container to add PAG refrigerant oil. This will ensure that the oil remains as moisture-free as possible. |
• | Have everything you need ready to allow you to perform all operations quickly when opening an A/C system. Do not leave the A/C system open any longer than necessary. |
• | Evacuate and recharge any A/C system that has been opened. |
All service parts are dehydrated and sealed before shipping. They should remain sealed until just before making connections. All the parts should be at room temperature before uncapping. This prevents condensation of moisture from the air from entering the system. Reseal all parts as soon as possible if the caps have been removed but the connections cannot be made promptly.
Caution: Use only refillable refrigerant tanks that are authorized for the charging station being used. The use of other tanks may cause personal injury or void the warranty. Refer to the Manufacturer's instructions for the charging station.
Caution: Refer to Protective Goggles and Glove Caution in the Preface section.
A charging station discharges, evacuates, and recharges an air conditioning system with one hook-up. Filtering during the recovery cycle together with filtering during the evacuation cycle ensures a supply of clean, dry refrigerant for A/C system charging.
• | Never use the R-134a charging station on a system charged with R-12. The refrigerants and the oils are not compatible and must never be mixed in even the smallest amount. Mixing refrigerant residue will damage the equipment. |
• | Never use adapters which convert from one size fitting to another. This will allow contamination which may cause system failure. |
Refer to the manufacturer's instructions for all initial setup procedures and all maintenance procedures. There are many charging stations available. All perform the various tasks required to discharge the system and recover refrigerant, evacuate the system, add a measured amount of oil, and recharge an air conditioning system with a measured amount of refrigerant.
A charging station will have controls and indicators to allow the operator to control and monitor the operation in progress. Refer to the manufacturer's instructions for details. These can be expected to include:
Important: Use only a refrigerant tank that is designed for the charging station in use. The unit's overfill limitation mechanism is calibrated specifically for use with this tank. The tank's valves are also specifically for this unit.
Important: If there is no refrigerant in the system, do not continue with the recovery operation. This will draw air into the recovery tank.
Notice: Never reuse refrigerant oil. Damage to the A/C system may result. Dispose of the refrigerant oil properly.
Important: Some A/C system PAG lubricating oil may be removed with the refrigerant during recovery. The amount of oil removed varies. A charging station separates the oil from the refrigerant and allows a means of determining how much oil was removed. Replace the same amount of oil when you recharge the system. Refer to the manufacturer's instructions for the charging station in use.
Important: If the control indicator shows that the refrigerant tank is full during the recovery process and the unit shuts OFF, install an empty unit tank to store the refrigerant needed for steps later in the procedure. Do not use any other type of tank.
The unit tank must contain a sufficient amount of R-134a refrigerant for charging. Check the amount of refrigerant in the tank. If there is less than 3.6 kg (8 lbs) of refrigerant, add new refrigerant to the tank. Refer to the manufacturer's instructions for adding refrigerant.
Important: Refer to the manufacturer's instructions for the charging station in use. It is necessary to evacuate the system before recharging it with new or recycled refrigerant.
Important: Change the vacuum pump oil frequently. Refer to the manufacturer's instructions for the charging station in use.
Any oil removed from the A/C system during the recovery process must be replenished at this time.
• | Keep the oil bottles tightly capped at all times to protect the oil from moisture and contamination. |
• | Never open the oil injection valve while there is positive pressure in the A/C system. This will result in oil blow-back through the bottle vent. You must have A/C system vacuum for this operation. |
• | Never let the oil level drop below the pick-up tube while charging or replenishing the system. This will allow air into the A/C system. |
Important: Evacuate the air conditioning system before charging.
Sometimes the total charge does not transfer into the A/C system. There are 2 reasons why this may occur.