Exhaust Manifold Replacement 1.2L
Removal Procedure
Warning: In order to avoid being burned, do not service the exhaust system while it is still hot. Service the system when it is cool.
- Remove the fuel pump fuse.
- Start the engine. After it stalls, crank the engine after it stalls for 10 seconds to rid the fuel system of fuel pressure.
- Disconnect the oxygen sensor connector.
- Remove the catalytic converter. Refer to
Catalytic Converter Replacement
- Remove the exhaust manifold.
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
- Install the exhaust manifold retaining bolts/nuts and tighten.
• | The exhaust manifold retaining bolts to
25 N·m (18.4 lb ft). |
• | The exhaust manifold retaining nuts to
20 N·m (14.7 lb ft). |
- Install the catalytic converter. Refer to
Catalytic Converter Replacement
- Connect the heater outlet hose from the coolant pipe.
- Install the exhaust manifold heat shield and tighten to
15 N·m (11 lb ft).
- Connect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection.
Exhaust Manifold Replacement 1.4L
Removal Procedure
Warning: Refer to Battery Disconnect Warning in the Preface section.
- Disconnect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
- Disconnect the upper oxygen sensor connector.
- Remove the exhaust manifold heat shield with engine oil indicator tube.
- Remove the exhaust front pipe. Refer to
Front Pipe Replacement.
Note: The exhaust manifold and the catalytic converter are one piece.
- Remove the exhaust manifold with the gasket.
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
Note: Check the exhaust gasket surface whether cracks or damages or not.
- Install the exhaust manifold with the gasket and tighten.
• | The exhaust manifold nuts to 20 N·m (14.7 lb ft). |
• | The exhaust manifold lower bracket bolts to 20 N·m (14.7 lb ft). |
- Install the exhaust front pipe. Refer to
Front Pipe Replacement.
- Install the exhaust manifold heat shield with the engine oil indicator tube and tighten to
8 N·m (70.8 lb in).
- Connect the upper oxygen sensor connector.
- Connect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection.