Step | Action | Yes | No |
---|---|---|---|
1 | Verify the customer complaint. Are the customer concerns verified? | Go to Step 2 | System OK |
2 | Move controls other that the temperature adjustment. Is an excessive effort required to move the controls? | Go to Step 15 | Go to Step 3 |
3 | Move the temperature control. Is an excessive effort required to move the controls? | Go to Step 6 | Go to Step 4 |
4 | Move the temperature control. Does the temperature door move too easily? | Go to Step 5 | System OK |
5 | Remove the cable from the controller. Does the knob turn freely, without the click stops? | Go to Step 15 | -- |
6 | Check the cables for improper routing, kinks, wiring interference, or other instrument panel interference. Is there a problem? | Go to Step 7 | Go to Step 8 |
7 | Repair as needed. Is the repair complete? | System OK | -- |
8 |
Is there any door binding? | Go to Step 9 | Go to Step 12 |
9 | Check a binding door for shaft alignment, a bent shaft, or a warped case. Is the door seal OK? | Go to Step 10 | Go to Step 11 |
10 |
Is the repair complete? | System OK | -- |
11 | Repair the door seal, as needed. Is the repair complaint? | System OK | -- |
12 | Check for control binding. Does the control bind? | Go to Step 14 | Go to Step 13 |
13 |
Is the repair complete? | System OK | -- |
14 |
Does the control bind? | Go to Step 15 | Go to Step 16 |
15 | Replace the control. Is the repair complete? | System OK | -- |
16 | Replace the cable. Is the repair complete? | System OK | -- |