Removal Procedure
Warning: Refer to Battery Disconnect Warning in the Preface section.
Note: Do not remove the IAT sensor from the air cleaner outlet hose. Replace only the air cleaner outlet hose assembly with the IAT sensor attached, if necessary.
- Disconnect the negative battery cable.
- Disconnect the intake air temperature (IAT) sensor connector.
- Loosen the clamp at the air cleaner outlet hose and replace the air cleaner outlet hose assembly with the IAT sensor attached.
Installation Procedure
- Install the air cleaner outlet hose with the IAT sensor attached.
- Connect the IAT sensor connector.
- Connect the negative battery cable.