The controller area network (CAN) high speed serial data buses are used to communicate information between the control modules. Typical data transmission speeds must be high enough to ensure that a required real-time response is maintained. The CAN serial data circuits also communicate directly to the data link connector (DLC). Messages are interpreted by the externally connected CANdi module which acts as a transceiver for the scan tool.
The ignition voltage is between 9.0 volts and 19.0 volts.
CAN BUS off for 5 seconds.
DTC U0073 is a Type A DTC.
DTC U0073 is a Type A DTC.
• | An intermittent condition is likely to be caused by a short on the CAN serial data circuits. |
• | This DTC cannot be retrieved with a current status. Diagnosis is accomplished using the symptom Scan Tool Does Not Communicate with CAN Device. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.