• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Ignition 1 Voltage | -- | -- | -- | P0400, P0402 |
Solenoid Control | P0403 | -- | P0403 | P0400, P0402 |
5-Volt Reference | P0107, P0404, P0405 | P0404, P0405 | -- | P0400, P0402 |
EGR Position Sensor Signal | P0403, P0405 | P0404, P0406 | P0404, P0406 | P0400, P0402 |
Low Reference | -- | P0404, P0406 | -- | P0400, P0402 |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Engine operating in Closed Loop. Parameter Normal Range: 0.6-0.8 Volts | |||
Ignition 1 Voltage | 0.7 Volts | -- | -- |
5-Volt Reference | 0.7 Volts | 0 Volts | 1.5 Volts |
EGR Position Sensor Signal | 0 Volts | 5 Volts | 5 Volts |
EGR Solenoid Control | 3.7 Volts | -- | -- |
Low Reference | -- | 5 Volts | -- |
Voltage is provided to the exhaust gas recirculation (EGR) valve by the ignition 1 voltage circuit through a fuse. Ground is provided to the EGR valve on the control circuit by a low side driver within the engine control module (ECM). The ECM monitors the voltage on the control circuit of the EGR valve to determine if a failure is present.
The ECM monitors the position of the EGR valve through the EGR valve position sensor. The EGR valve position sensor sends a feedback voltage on the signal circuit to the ECM. The EGR position sensor voltage varies depending on the position of the EGR valve.
• | The ignition is ON. |
• | The ignition 1 voltage is between 10-16 volts. |
• | The DTCs run continuously once the above conditions are met. |
• | DTCs P0400, P0402, P0403, P0405, and P0406 are not set. |
• | The engine is running. |
• | The EGR valve is closed. |
• | The DTC runs continuously once the above conditions are met. |
The ECM detects an open, short to ground or voltage on the control circuit of the EGR valve for greater than 2 seconds.
The ECM detects the learned position of the EGR pintle position is out of range for greater than 2 seconds.
The ECM detects the EGR position sensor is less than 1 volt.
The ECM detects the EGR position sensor is greater than 4.8 volts.
• | DTC P0403, P0405, and P0406 are Type A DTCs. |
• | DTC P0404 is a Type B DTC. |
• | DTC P0403, P0405, and P0406 are Type A DTCs. |
• | DTC P0404 is a Type B DTC. |
If a shared 5-volt reference circuit is shorted to ground or shorted to a voltage, other 5-volt reference circuits may be affected.
Exhaust Gas Recirculation (EGR) System Description
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
⇒ | If any of the DTCs are set, refer to DTC P0652 or P0653. |
⇒ | If the test lamp does not illuminate, test the ignition 1 voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition 1 voltage circuit fuse is open, test all components connected to the ignition 1 voltage circuit and replace as necessary. |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
Important: The 5-volt reference circuits are internally and externally connected at the ECM. Other component DTCs may be set. If other DTCs are set, review the electrical schematic and diagnose the applicable circuits and components.
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
Important: The EGR must be near 20°C (68°F) in order for an accurate measurement.
⇒ | If not within the specified range, replace the EGR valve. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for engine control module replacement, setup, and programming |