For 1990-2009 cars only

Generator Usage Gasoline Engines

Application

Description

2.0L

Amperage

85 A

Type

CS-128D

2.5L

Amperage

120 A

Type

CS-121 DIF

Generator Usage Diesel Engine

Description

Specification

Unit

Standard

Type

--

AD237

Capacity

AH

125

Regulator Type

--

Multi/Non RVC

Regulator Voltage

V

14.6 ± 0.25 at Tb=25°C

6,000 RPM

50% Load

Brush

  • Length

mm (in)

21.8

  • Number

EA

2

  • Minimum Length

mm (in)