Removal Procedure
Warning: Refer to Battery Disconnect Warning in the Preface section.
- Disconnect the negative battery cable.
- Disconnect the throttle cable by opening the throttle and moving the cable through the release slot.
- Disconnect the vacuum hose from the intake manifold tuning (IMT) valve actuator.
Note: Ensure the IMT valve flap is closed before removing the IMT valve.
- Remove the IMT actuator and the IMT valve.
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
- Install the IMT valve and the IMT actuator and tighten.
• | The IMT valve retaining bolts to
12 N·m (106 lb in). |
• | The IMT actuator retaining bolts to
12 N·m (106 lb in). |
- Connect the vacuum hose to the IMT actuator.
- Connect the throttle cable.
- Connect the negative battery cable.