Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Inspect the F12 fuse. Is the F12 fuse open? | -- | Go to Step 2 | Go to Step 3 |
2 | Replace the F12 fuse. Is the repair complete? | -- | System OK | -- |
3 |
Is the voltage within the specified value? | 11-14 V | Go to Step 4 | Go to Step 5 |
4 |
Is the repair complete? | -- | System OK | -- |
5 | Measure the voltage between terminal A1 and the ground. Is the voltage as specified? | 0 V | Go to Step 6 | Go to Step 7 |
6 |
Is the repair complete? | -- | System OK | -- |
7 |