Removal Procedure
- Loosen the air cleaner outlet duct clamp at the air cleaner assembly.
- Remove the air cleaner outlet duct from the air cleaner assembly.
- Remove the air cleaner assembly attachment bolts.
- Remove the air cleaner inlet duct from the air cleaner assembly.
- Remove the air cleaner assembly.
Installation Procedure
- Install the air cleaner assembly.
Caution: Refer to Fastener Caution in the Preface section.
- Install the air cleaner assembly attachment bolts and tighten to
10 N·m (89 lb in).
- Install the air cleaner inlet duct to the air cleaner assembly.
- Install the air cleaner outlet duct to the air cleaner assembly using the duct clamps and tighten to
3 N·m (27 lb in).