HVAC Control Module Replacement RHD
Removal Procedure
- Remove the glove box assembly. Refer to
Instrument Panel Compartment Replacement
.
- Remove left side floor duct. Refer to
Floor Air Outlet Duct Replacement - Left Side
.
- Locate the HVAC control module (1) on the left
side of the HVAC module assembly (2).
- Disconnect the HVAC control module electrical connectors (1
- 3).
Important: Make sure the HVAC control module electrical
connectors are disconnected before removing the HVAC control module to HVAC module
assembly retaining screws (1). The HVAC control module to HVAC module assembly
retaining screws (1) contact the HVAC control module (2) circuit board
and can short on removal.
- Remove the HVAC control module to HVAC module assembly retaining screws (1).
- Remove HVAC control module (2).
Installation Procedure
- Install the HVAC control module (1) to the HVAC
module assembly (2).
Notice: Refer to Fastener Notice in the Preface section.
Important: The HVAC control module to HVAC module assembly
retaining screws (1 - 4) should be tightened in the sequence shown to prevent damage
to HVAC control module circuit board.
- Install the HVAC control module to HVAC module assembly retaining screws (1
- 4).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the electrical connectors (1 - 3) to the
HVAC control module.
- Install left side floor duct. Refer to
Floor Air Outlet Duct Replacement - Left Side
.
- Install the glove box assembly. Refer to
Instrument Panel Compartment Replacement
.
- If re-programming is required. Refer to
Control Module References
.
- Perform HVAC system relearn. Refer to
HVAC Control Module Programming and Setup
.