Removal Procedure
- Remove the Instrument Panel Centre Trim Panel. Refer to
Instrument Panel Center Trim Panel Replacement.
- Disconnect the auxiliary mode door actuator electrical
connector (3).
- Remove the auxiliary mode door actuator to HVAC module assembly retaining
screws (2).
- Remove the auxiliary mode door actuator (3) from the HVAC module
assembly (4).
Installation Procedure
- Align the actuator drive gear (1) with the
door shaft spline (2).
- Install the auxiliary mode door actuator (3)
to the HVAC module assembly (4)..
Notice: Refer to Fastener Notice in the Preface section.
- Install the auxiliary mode door actuator to HVAC module assembly retaining screws (2).
Tighten
Tighten the bolts to 1.2 N·m (9 lb ft).
- Connect the auxiliary mode door actuator electrical connector (3).
- Install the Instrument Panel Centre Trim Panel. Refer to
Instrument Panel Center Trim Panel Replacement.
- Perform HVAC system relearn. Refer to
HVAC Control Module Programming and Setup.