The numbers below refer to the step numbers on the diagnostic table.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics. Connector End View Reference: Component Connector End Views. DEFINITION: The temperature cannot be adjusted, or cooling is insufficient during A/C operation. | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |
2 | Check operation of air mix doors to make sure they are not jammed or broken Is the air mix door broken or jammed? | - | Go to Step 3 | |
3 |
Important: All DTCs that are set must be diagnosed first unless you were sent to this diagnostic from a specific DTC diagnostic.
Does the blower motor operate in any speed position? | -- | Go to Step 4 | Go to Blower Motor Inoperative. |
4 | Does the blower motor operate at the desired speeds? | -- | Go to Step 5 | Go to Blower Motor Malfunction |
5 |
Does the recirculation door move from the recirculation position to the outside air position? | -- | Go to Step 6 | |
6 |
Important: The ambient air temperature must be above 3°C (38°F).
Does the A/C compressor operate? | -- | Go to Step 7 | |
7 | Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 8 |
8 | Inspect the inside air temperature sensor for proper installation. Refer to Inside Air Temperature Sensor Replacement. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 9 |
9 |
Does the paper stay in place? | -- | Go to Step 10 | Go to Step 17 |
10 |
Does the scan tool indicate the sensor temperatures is within 3°C (5°F) of the thermometer temperature? | -- | Go to Step 11 | Go to Step 14 |
11 |
Is the Solar Sensor parameter greater than the specified value? | 220 Counts | Go to Step 12 | Go to Step 18 |
12 |
Do the counts change? | -- | Go to Step 13 | Go to Step 18 |
13 | Test the resistance of the ambient air temperature sensor. Refer to Sensor Resistance Table. Is the resistance near the value in the Sensor Resistance Table? | -- | Go to Testing for Intermittent Conditions and Poor Connections. | Go to Step 15 |
14 | Test the resistance of the inside air temperature sensor. Refer to Sensor Resistance Table. Is the resistance near the value in the Sensor Resistance Table? | -- | Go to Step 19 | Go to Step 17 |
15 | Inspect for poor connections at the harness connector of the ambient air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 17 |
16 | Inspect the aspirator tube for an air leak or obstruction. Did you find and correct the condition? | -- | Go to Step 24 | -- |
17 | Inspect for poor connections at the harness connector of the inside air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 20 |
18 | Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 21 |
19 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs. Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 23 |
20 | Replace the inside air temperature sensor. Refer to Inside Air Temperature Sensor Replacement. Did you complete the replacement? | -- | Go to Step 24 | -- |
21 | Replace the sunload sensor. Refer to Sun Load Temperature Sensor Replacement. Did you complete the replacement? | -- | Go to Step 24 | -- |
22 | Replace the ambient air temperature sensor. Refer to Ambient Air Temperature Sensor Replacement. Did you complete the replacement? | -- | Go to Step 24 | -- |
23 | Replace the HVAC control module. Refer to Control Module References. Did you complete the replacement? | -- | Go to Step 24 | -- |
24 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |