Important:
• | This procedure tests On/Off type solenoid valves. |
• | Visually inspect the physical condition of the solenoid before testing.
Inspect the O-rings before and after the test to be sure that they are not cut or
damaged. |
- Remove the shift solenoid valve from the control valve body or the torque converter
clutch (TCC) solenoid valve from the transmission case. Refer to Control and Shift
Solenoid Replacement or Torque Converter Clutch Pulse Width Modulation (TCC PWM)
Solenoid, TCC Solenoid and Wiring Harness.
- Install the TCC solenoid valve, the 1-2
shift solenoid valve or the 2-3 shift solenoid valve into bore number 2
of the
J-44246
and install the
factory retainer clip to retain the solenoid.
Important: The supplied solenoid testing harness will
not power the 4L60-E TCC On/Off solenoid. To energise this solenoid, apply battery,
12-volt, positive (+) and negative (-) to the TCC On/Off solenoid wiring
harness using connector test adapter kit
J 35616
. Use terminal E, Red, Power, and terminal T, Black,
Ground. Refer to the
Component Connector End Views
.
- Connect the solenoid testing harness supplied with the
J-44246
to the solenoid.
Important: Do not use air pressure in excess of 827.4 kPa
(120 psi). Excessive pressure will not allow the solenoid ball check valve
to seat properly. Recommended air pressure is 344.75 kPa (50 psi).
- Apply compressed air to the
J-44246
.
- Air should flow through the solenoid. If air does not flow through the
solenoid, replace the solenoid. Refer to Control and Shift Solenoids Replacement.
- Connect the solenoid testing harness to the 12-volt positive (+) and negative
(-) battery terminals.
- Observe if the solenoid is operating electrically. An audible clicking
noise can be heard when connecting or disconnecting power.
Important:
• | All solenoids need to be energised to seal. |
• | A small amount of air leakage is normal +/- 21 kPa (+/-
3 psi). |
- Observe the air flow through the solenoid. The flow will completely or nearly
completely stop. Replace the solenoid if there continues to be an obvious air leak
when the solenoid is energised.
Important: Inspect the O-rings after the test to be
sure that they are not cut or damaged.
- Install the shift solenoid valve into the control valve body or the TCC solenoid
valve into the transmission case. Refer to Control and Shift Solenoids Replacement
or Torque Converter Clutch Pulse Width Modulation (TCC PWM) Solenoid, TCC solenoid
and Wiring Harness.