Removal Procedure
- Turn the ignition OFF.
Important: Do not remove the engine Control Module (ECM)
from the ECM bracket .
Do not remove the ECM redundant ground wire from
the ECM.
- Remove the remote earth post bracket to engine front cover retaining bolts.
- Remove the camshaft position (CMP) actuator valve
electrical connector (1) from the CMP sensor (2).
- Remove the CMP actuator solenoid valve to engine front
cover retaining bolt (1).
- Remove the CMP actuator valve (2) from the engine front cover.
- Inspect the CMP actuator valve seal and replace as necessary.
Installation Procedure
- Inspect the CMP actuator valve seal for damage. Replace the seal if necessary.
- Install the CMP actuator valve (2) to the engine front
cover.
Notice: Refer to Fastener Notice in the Preface section.
- Install the CMP actuator solenoid valve to engine front cover retaining bolt (1).
Tighten
Tighten the bolt to 10 N·m (89 lb in).
- Install the CMP actuator valve electrical connector
(1) to the CMP sensor (2).
- Install the remote earth post bracket to engine front cover retaining
bolts.