• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
I/P Fuse Block B+ | 1 | 1 | -- | -- |
Door Lock Switch Lock Signal | B3150 00 | 2 | 2 | -- |
Door Lock Switch Unlock Signal | B3140 00 | 2 | 2 | -- |
All Lock Relay Control | B3135 00 | B3135 00 | 1 | -- |
Door Latch Assembly Control | 1 | 1 | 1 | -- |
Driver Unlock Relay Control | B3125 00 | B3125 00 | B3125 00 | -- |
Passenger Unlock Relay Control | B3130 00 | B3130 00 | B3130 00 | -- |
Window/Door Lock Switch Ground | -- | 2 | 2 | -- |
Relay Ground | -- | 1 | 1 | -- |
1. Door Lock Malfunction 2. Door Lock Switch Malfunction |
The body control module (BCM) supplies and monitors a reference voltage to the door lock/window switch through the door lock switch lock and unlock signal circuits. The door lock/window switch also receives a constant ground source. If a door lock switch is placed in the lock position or unlock position, the reference voltage is taken directly to ground and the BCM detects the voltage drop on the signal circuit.
The system voltage is 9-16 volts.
The BCM detects a short to ground in the unlock switch signal circuit.
The BCM detects a short to ground in the lock switch signal circuit
The power door lock switch will malfunction.
• | The DTC will be current for as long as the fault is present. |
• | When the fault is no longer present, the DTC will become a history DTC. |
• | A history DTC will clear after 50 ignition cycles. |
Door Lock/Indicator Schematics
Power Door Locks Description and Operation
Control Module References for scan tool information
Ignition ON, observe the scan tool Central Door Lock Switch and Central Door Unlock Switch parameters while using the door lock/window switch. The parameter should change between Inactive and Active when changing between the commanded states.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal 15 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit terminal 5 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If less than the specified value, replace the door lock/window switch. |
⇒ | If greater than the specified range, replace the door lock/window switch. |
⇒ | If greater than the specified range, replace the door lock/window switch |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup and programming |