Instrument Panel Insulator Panel Replacement - Left Side RHD
Removal Procedure
- Grasp the I/P lower trim plate assembly (1) and carefully
pull downward to disengage the retaining clips.
- Remove the courtesy lamp socket assembly (2) from the left lower trim
plate by turning the socket counter-clockwise.
- Remove the I/P lower trim plate assembly (1).
Installation Procedure
- Install the courtesy lamp socket assembly (2) to the
I/P lower trim plate assembly (1).
- Align the I/P lower trim plate assembly (1) to the I/P.
- Attach the I/P lower trim plate assembly (1) to the I/P by engaging the
retaining clips.
- Ensure all clips are located correctly.