GM Service Manual Online
For 1990-2009 cars only

Air Inlet Valve Actuator Replacement RHD

Removal Procedure

  1. Remove the I/P lower trim plate assembly. Refer to Instrument Panel Insulator Panel Replacement - Left Side.
  2. Remove the I/P compartment assembly. Refer to Instrument Panel Compartment Replacement.

  3. Object Number: 1958813  Size: SH
  4. Disconnect the recirculation actuator electrical connector (1).

  5. Object Number: 1958815  Size: SH
  6. Remove the recirculation actuator to HVAC module assembly retaining screws (2).
  7. Remove the recirculation actuator (1) from the HVAC module assembly (3).
  8. Inspect air intake door shaft end for damage, also check the air intake door for full movement, open/close. If damage is evident, replace the air intake housing. Refer to Air Inlet Assembly Replacement.

Installation Procedure


    Object Number: 1958815  Size: SH
  1. Install the air intake recirculation actuator (1) to the HVAC module assembly (3).
  2. Notice: Refer to Fastener Notice in the Preface section.

  3. Install the recirculation actuator (1) to HVAC module assembly retaining screws (2).
  4. Tighten
    Tighten the screws to 1.2 N·m (9 lb ft).


    Object Number: 1958813  Size: SH
  5. Connect the recirculation actuator electrical connector (1).
  6. Install the I/P lower trim plate assembly. Refer to Instrument Panel Insulator Panel Replacement - Left Side.
  7. Install the I/P compartment assembly. Refer to Instrument Panel Compartment Replacement.
  8. Perform HVAC system relearn. Refer to HVAC Control Module Programming and Setup.