• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
5-Volt Reference | P0122, P0222, P0641, P2106, P2110 | -- | P0122, P0222, P2106, P2110, P2135 | P0223, P0641, P2106, P2110, P2135 | -- |
TP Sensor 1 Signal | P0122, P2135 | P2135 | P0123, P2135 | P0123, P2135 | P2135 |
TP Sensor 2 Signal | P0222, P2135 | P2135 | P0222, P2135 | P0223, P2135 | P2135 |
Low Reference | -- | -- | P0123, P2106, P2110 | -- | -- |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: The ignition is ON and the engine is OFF. Parameter Normal Range: TP Sensor 1 7-21% | |||
5-Volt Reference | 0% | 0% | 30-40% |
TP Sensor 1 Signal | 0% | 80-90% | 85-99% |
Low Reference | -- | 85-95% | -- |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: The ignition is ON and the engine is OFF. Parameter Normal Range: TP Sensor 2 7-21% | |||
5-Volt Reference | 80-90% | 80-90% | 0% |
TP Sensor 2 Signal | 80-90% | 80-90% | 0% |
Low Reference | -- | 0% | -- |
The throttle body assembly contains 2 throttle position (TP) sensors. The TP sensors are mounted to the throttle body assembly and are not serviceable. The TP sensors provide a signal voltage that changes relative to throttle blade angle. The engine control module (ECM) supplies the TP sensors with a common 5-volt reference circuit, a common low reference circuit, and 2 independent signal circuits.
• | The ignition is ON or the engine is operating. |
• | The DTCs runs continuously when the above condition is met. |
The ECM detects that the TP sensor 1 voltage is less than 0.25 volt for less than 1 second.
The ECM detects that the TP sensor 1 voltage is greater than 4.8 volts for less than 1 second.
The ECM detects that the TP sensor 2 voltage is less than 0.25 volt for less than 1 second.
The ECM detects that the TP sensor 2 voltage is greater than 4.8 volts for less than 1 second.
The ECM detects that TP sensor 1 and TP sensor 2 disagree more than 4.5 percent for less than 1 second.
• | DTC P0122 and P0123 are type B DTCs |
• | The ECM uses throttle position (TP) sensor 2 for throttle control. |
• | DTC P0222 and P0223 are type B DTCs |
• | The ECM uses throttle position (TP) sensor 1 for throttle control. |
• | DTC P2135 is a type A DTC. |
• | The ECM commands the TAC system to operate in a Reduced Engine Power mode. |
• | The ECM commands the reduced engine power indicator ON. |
• | DTCs P0122, P0123, P0222, and P0223 are type B DTCs. |
• | DTC P2135 is a type A DTC. |
• | If a shared 5-volt reference circuit is shorted to ground or shorted to a voltage, other 5-volt reference circuits may be affected. |
• | The scan tool 5-volt reference parameter should display between 4.8-5.2 volts. |
Throttle Actuator Control (TAC) System Description
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
⇒ | If DTC P0641 is set, refer to DTC P0641 or P0651 . |
⇒ | If greater than the specified value, test the low reference circuit for a short to voltage, or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If TP sensor 1 is greater than specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If TP sensor 1 is less than the specified range, test the signal circuit for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If TP sensor 2 is less than specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If TP sensor 2 is greater than specified range, test the signal circuit for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified value, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified value, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for engine control module replacement, setup, and programming |