Diagnostic Instructions
DTC Descriptor
DTC P0443: Evaporative Emission (EVAP) Purge Solenoid Control Circuit
Circuit/System Description
The evaporative emission (EVAP) canister purge valve is used to purge fuel vapor from the EVAP canister to the intake manifold. The EVAP canister purge valve is pulse width modulated (PWM). Ignition voltage is supplied directly to the EVAP canister purge
valve. The engine control module (ECM) controls the solenoid by grounding the control circuit with a solid state device called a driver. The driver is equipped with a feedback circuit that is pulled-up to a voltage. The ECM can determine if the control circuit
is open, shorted to ground, or shorted to a voltage by monitoring the feedback voltage.
Conditions for Running the DTC
• | DTC P0606 is not set for Euro IV emissions only. |
• | The ignition voltage is greater than 11 volts. |
• | The DTC runs continuously once the above conditions are met. |
Conditions for Setting the DTC
The ECM detects the EVAP purge solenoid control circuit is open, shorted to ground, or shorted to voltage.
Action Taken When the DTC Sets
DTC P0443 is a Type B DTC.
Conditions for Clearing the DTC
DTC P0443 is a Type B DTC.
Reference Information
Schematic Reference
Engine Controls Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Evaporative Emission Control System Description
Electrical Information Reference
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Verification
Ignition ON, command the EVAP Purge Solenoid ON and OFF with a scan tool. You should hear the solenoid click when commanded ON and OFF.
Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the EVAP purge solenoid.
- Ignition ON, verify a test lamp illuminates between the ignition 1 voltage circuit terminal 1 or A and ground.
⇒ | If the test lamp does not illuminate, test the ignition 1 voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition 1 voltage circuit fuse is open, test all components connected
to the ignition 1 voltage circuit and replace as necessary. |
- Ignition OFF, connect a test lamp between the control circuit terminal 2 or B and the ignition 1 voltage circuit terminal 1 or A.
- Ignition ON, command the EVAP Purge Solenoid to 100 percent with a scan tool, and back to 0 percent. The test lamp should respond to the commanded state.
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
- If all circuits test normal, test or replace the EVAP purge solenoid.
Component Testing
- Ignition OFF, disconnect the harness connector at the EVAP purge solenoid.
- Test for 18-28 ohms of resistance between the control terminal 2 or B and the ignition 1 voltage terminal 1 or A.
⇒ | If not within the specified range, replace the EVAP purge solenoid. |
- Test for infinite resistance between each terminal and the EVAP purge solenoid housing.
⇒ | If not the specified value, replace the EVAP purge solenoid. |
Repair Instructions
Perform the
Diagnostic Repair Verification after completing the diagnostic procedure.