Removal Procedure
Warning: Refer to Battery Disconnect Warning in the Preface section.
- Disconnect the negative battery cable.
- Open the liftgate.
- Remove the liftgate lamp access cover.
- Remove the liftgate lamp assembly nuts.
- Remove the liftgate lamp assembly.
- Disconnect the electrical connector.
Installation Procedure
- Connect the electrical connector.
Caution: Refer to Fastener Caution in the Preface section.
- Install the lamp assembly with the nuts and tighten to
3 N·m (27 lb in).
- Install the liftgate lamp access panels.
- Close the liftgate.
- Connect the negative battery cable.