GM Service Manual Online
For 1990-2009 cars only

Blower Motor Replacement LHD

Removal Procedure

  1. Remove the right closeout insulator panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side .
  2. Remove the instrument panel (I/P) compartment. Refer to Instrument Panel Compartment Replacement .

  3. Object Number: 1951025  Size: SH
  4. Disconnect the blower motor electrical connector.

  5. Object Number: 1951027  Size: SH
  6. Disconnect the blower motor processor electrical connector.

  7. Object Number: 1951030  Size: SH
  8. Remove the blower motor retaining screws (1).

  9. Object Number: 1951035  Size: SH
  10. Remove the blower motor.

Installation Procedure


    Object Number: 1951035  Size: SH
  1. Install the blower motor.
  2. Notice: Refer to Fastener Notice in the Preface section.


    Object Number: 1951030  Size: SH
  3. Install the blower motor retaining screws (1).
  4. Tighten
    Tighten the screws to 1.5 N·m (13 lb in).


    Object Number: 1951027  Size: SH
  5. Connect the blower motor processor electrical connector.

  6. Object Number: 1951025  Size: SH
  7. Connect the blower motor electrical connector.
  8. Install the I/P compartment. Refer to Instrument Panel Compartment Replacement .
  9. Install the right closeout insulator panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side .

Blower Motor Replacement RHD

Removal Procedure

    Caution: Refer to Safety Glasses Caution in the Preface section.

  1. Remove the glove box assembly. Refer to Instrument Panel Compartment Replacement .
  2. Remove the left floor air outlet duct. Refer to Floor Air Outlet Duct Replacement - Left Side .

  3. Object Number: 1950927  Size: SH
  4. Disconnect the blower motor electrical connector (1).

  5. Object Number: 1951004  Size: SH
  6. Remove the blower motor to blower assembly retaining screws (1).

  7. Object Number: 1950930  Size: SH
  8. Remove the blower motor (2) from the blower assembly (1).

Installation Procedure


    Object Number: 1950930  Size: SH
  1. Install the blower motor (2) to the blower assembly (1).
  2. Notice: Refer to Fastener Notice in the Preface section.


    Object Number: 1951004  Size: SH
  3. Install the blower motor to blower assembly retaining screws (1).
  4. Tighten
    Tighten the screws to 2 N·m(18lb in).


    Object Number: 1950927  Size: SH
  5. Connect the blower motor electrical connector (1).
  6. Install the left floor air outlet duct. Refer to Floor Air Outlet Duct Replacement - Left Side .
  7. Install the glove box assembly. Refer to Instrument Panel Compartment Replacement .