• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Horn Relay Control | B2750 00 | B2750 00 | B2750 00 | -- |
Horn Control | 2 | 2 | 1 | -- |
Horn Ground | -- | 2 | -- | -- |
Horn Switch Ground | -- | 2 | -- | -- |
|
The body control module (BCM) controls the horn relay by grounding the control circuit of the horn relay coil energizing the relay. When the horn relay is energized, the horn relay contacts close applying voltage through the horn fuse and the horn control circuit to the horns.
The DTC can only set only when the output is actively being requested by the BCM.
The BCM detects a short to ground, open, or short to voltage in the horn relay control circuit for approximately 125 milliseconds.
The BCM disables the output to the horn relay until the next ignition cycle.
• | The conditions for setting the DTC are no longer present. |
• | The current DTC will become history when the request for the output is removed. |
• | The history DTC will clear after 50 fault-free ignition cycles. |
Ignition ON, use scan tool Horn output control to command the horn relay On. The Horn Relay Command output data parameter should display On and the horn should sound.
⇒ | If the test lamp is always OFF, test the horn relay control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always ON, test the horn relay control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.