• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Backup Lamp Relay B+ | 1 | 1 | -- | -- |
Backup Lamp Relay Control | 1 | 1 | B2545 00 | -- |
Backup Lamps Control | 1 | 1 | 1 | -- |
Backup Lamp Ground - Left | -- | 1 | -- | -- |
Backup Lamp Ground - Right | -- | 1 | -- | -- |
1. Backup Lamps Malfunction |
When the transmission is placed in the REVERSE position, the transmission control module (TCM) sends a serial data message to the body control module (BCM). The message indicates that the gear selector is in the REVERSE position. The BCM applies ground to the backup lamp relay control circuit energizing the backup lamp relay coil. With the relay coil energized, the switch contacts close allowing battery voltage to flow from the BACKUP LP fuse to the left and right backup lamps. Once the driver moves the gear selector out of the REVERSE position, a message is sent by the TCM via serial data requesting the BCM to remove ground from the backup lamp relay control circuit.
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit terminal 87 for a short to ground. If the circuit tests normal, test or replace the backup lamp relay. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for an open/high resistance. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the backup lamps do not illuminate, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the inoperative backup lamp. |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |