Diagnostic Instructions
DTC Descriptors
DTC B0193 06: Blower Motor not Operating, Short to Ground or Open Circuit
Diagnostic Fault Information
Circuit
| Short to Ground
| Open/High Resistance
| Short to Voltage
| Signal Performance
|
Blower Motor control
| B0193 06
| B0193 06
| --
| --
|
Circuit Description
The blower motor speed control, battery positive and ground circuits enable the control module to operate. The HVAC control module provides a pulse width modulation signal to the blower motor in order to command the blower motor speed.
Conditions for Running the DTC
• | Ignition voltage is between 9-16 volts. |
Conditions for Setting the DTC
The blower motor draws more amperage than the HVAC control module is calibrated for.
Conditions for Clearing the DTC
• | The condition for setting the DTC is no longer present. |
• | The DTC can be cleared using a scan tool. |
Reference Information
Schematic Reference
HVAC Schematics
Connector End View Reference
Component Connector End Views
Electrical Information Reference
Scan Tool Reference
Control Module References
Circuit/System Verification
Ignition ON, operate the blower fan speed(s).
Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the blower motor.
- Ignition ON, connect test lamp at the battery positive voltage terminal A and ground.
⇒ | If the test lamp does not illuminate, test the battery positive voltage circuit for short to ground or an open/high resistance. |
- Connect test lamp between the battery positive voltage terminal A and the control circuit terminal B. The test lamp should dimly illuminate at high speeds and reduce in intensity as the blower speed is reduced.
⇒ | If the test lamp does not illuminate. Test the control circuit for short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If the test lamp stays illuminated all the time. Test the control circuit for short to ground. If the circuit tests normal, replace the HVAC control module. |
⇒ | If the test lamp does illuminate and change intensity. Test or replace the blower motor.. |
Repair Instructions
Perform the