GM Service Manual Online
For 1990-2009 cars only

Circuit Description

The powertrain control module (PCM) uses the crankshaft position (CKP) sensor and the camshaft position (CMP) sensor information to monitor the correlation between the crankshaft and camshaft positions. If the deviation between the crankshaft and CMP exceeds a calibrated amount DTC P0016 will set.

Conditions for Running the DTC

    • The engine is running.
    • The minimum voltage is 11 volts.
    • The variable camphaser is commanded to zero for more than 16 seconds.

Conditions for Setting the DTC

The deviation between the crankshaft and the camshaft positions exceeds a calibrated amount.

Action Taken When the DTC Sets

    • The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
    • The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.

Conditions for Clearing the MIL/DTC

    • The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
    • A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
    • A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
    • Clear the MIL and the DTC with a scan tool.

Diagnostic Aids

Important: Scan tool control of the CMP actuator solenoid is inhibited when DTC P0016 sets.

The following conditions may cause this DTC to set:

    • An improperly torqued harmonic balancer
    • A mis-built or mis-timed engine
    • A loose or missing crank damper bolt
    • The camphaser solenoid stuck open
    • The camphaser stuck in a position other than 0 degrees

Test Description

The number below refers to the step number on the diagnostic table.

  1. If this DTC sets, there is a problem with the CMP actuator solenoid high control circuit shorted to voltage or the solenoid stuck open.

Step

Action

Values

Yes

No

1

Did you perform the Diagnostic System Check-Engine Controls?

--

Go to Step 2

Go to Diagnostic System Check - Engine Controls

2

  1. Start the engine.
  2. Clear the DTCs with a scan tool.

Does the scan tool indicate that DTC P0013 failed this ignition?

--

Go to DTC P0013

Go to Step 3

3

  1. Observe the Freeze Frame/Failure Records for this DTC.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

--

Go to Step 4

Go to Diagnostic Aids

4

  1. Turn OFF the ignition.
  2. Inspect the crank damper bolt for the proper torque. Refer to Fastener Tightening Specifications and Crankshaft Balancer Replacement in Engine Mechanical.

Was the damper bolt at the proper torque?

 

Go to Step 5

Go to Crankshaft Balancer Cleaning and Inspection in Engine Mechanical

5

  1. Disconnect the camshaft position (CMP) actuator.
  2. Remove the CMP actuator solenoid. Refer to Camshaft Position Actuator Solenoid Valve Replacement .
  3. Connect a fused jumper wire between B+ and the CMP actuator high control circuit at the solenoid. Refer to Using Fused Jumper Wires in Wiring Systems.
  4. Jumper the low reference circuit of the camshaft position actuator solenoid to a good ground. Refer to Using Connector Test Adapters in Wiring Systems.

Does the pintle inside the CMP actuator solenoid move?

 

Go to Step 6

Go to Step 8

6

Inspect the CMP actuator for binding or being stuck. Refer to Camshaft Position Actuator Diagnosis in Engine Mechanical.

Did you find and correct the condition?

--

Go to Step 9

Go to Step 7

7

Inspect the engine for correct valve timing. Refer to Camshaft Timing Chain, Sprocket, and Tensioner Replacement in Engine Mechanical.

Did you find and correct the condition?

--

Go to Step 9

Go to Diagnostic Aids

8

Replace the camshaft position actuator solenoid. Refer to Camshaft Position Actuator Solenoid Valve Replacement .

Did you complete the replacement?

--

Go to Step 9

--

9

  1. Clear the DTCs with a scan tool.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

--

Go to Step 2

Go to Step 10

10

Observe the Capture Info with a scan tool.

Are there any DTCs that have not been diagnosed?

--

Go to Diagnostic Trouble Code (DTC) List

System OK