The numbers below refer to the step numbers on the diagnostic table.
This step tests the output from the blower motor switch. Loss of blower motor switch output would indicate a malfunctioning switch or a circuit malfunction in the supply voltage to the switch.
There are two ignition 3 voltage circuits at the HVAC control module. Test the circuit that provides the supply voltage to the blower motor switch.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions. | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 |
Does the blower motor operate in any of the speed positions? | Go to Blower Motor Malfunction | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 6 |
4 | Connect a test lamp between the blower motor supply voltage circuit and the blower motor ground circuit. Does the test lamp illuminate? | Go to Step 8 | Go to Step 5 |
5 | Test the ground circuit of the blower motor resistor assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 9 |
Does the test lamp illuminate? | Go to Step 9 | Go to Step 7 | |
Does the test lamp illuminate? | Go to Step 11 | Go to Step 12 | |
8 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 13 |
9 | Visually inspect the blower motor harness of the blower motor resistor assembly for an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 10 |
10 | Inspect for poor connections at the harness connector of the blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 14 |
11 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 16 | Go to Step 15 |
12 | Repair the ignition 3 voltage circuit of the blower motor switch. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 16 | -- |
13 | Replace the blower motor. Refer to Blower Motor Replacement . Did you complete the replacement? | Go to Step 16 | -- |
14 | Replace the blower motor resistor assembly. Refer to Blower Motor Resistor Assembly Replacement . Did you complete the replacement? | Go to Step 16 | -- |
15 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 16 | -- |
16 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |