Table 1: | HVAC Control Module Scan Tool Output Controls |
Table 2: | Auxiliary HVAC Control Module Scan Tool Output Controls |
Table 3: | PCM Scan Tool Output Controls |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
A/C Permission | Miscellaneous Tests | When you select ON, the HVAC control module changes the state of the A/C Permission parameter to Granted and transmits a clutch enable message to the PCM over the class 2 serial data circuit. The A/C compressor clutch engages and remains engaged until you select OFF. When you select OFF, the HVAC control module changes the state of the A/C Permission parameter to Withheld and transmits a clutch disable message to the PCM over the class 2 serial data circuit. |
HVAC Actuator Recalibration | -- | When you select RESET, the HVAC control module recalibrates the maximum and minimum door positions of each HVAC door. The ambient air temperature display is set to the current value of the Outside Air Temp. Raw parameter. |
Left Mix Motor | Motor/Actuator Tests | When you select ON, the HVAC control module commands the left air temperature actuator toward the maximum door position. The actuator moves the door to the full hot position. When you select OFF, the HVAC control module commands the left air temperature actuator toward the minimum door position. The actuator moves the door to the full cold position. |
Mode 1 Door Position | Motor/Actuator Tests | When you select ON, the HVAC control module commands the mode actuator toward the maximum door position. The actuator moves the door to the panel position. When you select OFF, the HVAC control module commands the mode actuator toward the minimum door position. The actuator moves the door to the floor position. |
Mode 2 Door Position | Motor/Actuator Tests | When you select ON, the HVAC control module commands the defroster actuator toward the maximum door position. The actuator moves the door to the defrost position. When you select OFF, the HVAC control module commands the defroster actuator toward the minimum door position. The actuator moves the door in the opposite direction of the defrost position. |
Right Mix Motor | Motor/Actuator Tests | When you select ON, the HVAC control module commands the right air temperature actuator toward the maximum door position. The actuator moves the door to the full cold position. When you select OFF, the HVAC control module commands the right air temperature actuator toward the minimum door position. The actuator moves the door to the full hot position. |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
Air Mix Door | Special Functions | When you select ON, the auxiliary HVAC control module commands the auxiliary air temperature actuator toward the maximum door position. The actuator moves the door to the full hot position. When you select OFF, the auxiliary HVAC control module commands the auxiliary air temperature actuator toward the minimum door position. The actuator moves the door to the full cold position. |
Blower Motor | Special Functions | When you select ON, the auxiliary HVAC control module commands the auxiliary blower motor to maximum speed. The auxiliary blower motor operates at maximum speed until you select OFF. The auxiliary HVAC control module must be in the ON state before selecting the output control. |
Console Door Position | Special Functions | When you select ON, the auxiliary HVAC control module commands the console mode actuator toward the maximum door position. The actuator moves the console mode door to the lower position. When you select OFF, the auxiliary HVAC control module commands the console mode actuator toward the minimum door position. The actuator moves the console mode door to the upper position. |
HVAC Actuator Recal. | Special Functions | When you select RESET, the auxiliary HVAC control module recalibrates the maximum and minimum door positions of each auxiliary HVAC door. |
Mode Door Position | Special Functions | When you select ON, the auxiliary HVAC control module commands the auxiliary mode actuator toward the maximum door position. The actuator moves the door to the upper position. When you select OFF, the auxiliary HVAC control module commands the auxiliary mode actuator toward the minimum door position. The actuator moves the door to the lower position. |
Water Valve | Special Functions | When you select ON, the auxiliary HVAC control module sends a class 2 serial data message to the HVAC control module to command the coolant bypass valve to the closed position. The coolant bypass valve solenoid is engaged and vacuum is applied to the coolant valve. The valve will close. When you select OFF, the auxiliary HVAC control module sends a class 2 serial data message to the HVAC control module to command the coolant bypass valve to the open position. The coolant bypass valve solenoid is disengaged and vacuum is removed from the coolant valve. The valve will open. |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
A/C Relay | Engine Output Controls | The engine must be running and the PCM must receive an A/C request from the HVAC control module in order to enable the output control. The PCM de-energizes the A/C compressor clutch relay when you select OFF. The relay remains de-energized until you select ON. |