Step | Action | Yes | No |
---|---|---|---|
1 |
Does warm air flow out of the rear HVAC outlet ducts? | Go to Step 5 | Go to Step 2 |
2 | Using an external vacuum source, apply vacuum to the coolant by pass valve assembly. Does the valve open and close? | Go to Step 5 | Go to Coolant Bypass Valve Replacement in Heating, Ventilation and Air Conditioning |
3 | With the coolant by-pass valve removed, inspect the valve for binding. Does the valve move freely? | Go to Step 5 | Go to Step 4 |
4 | Replace the coolant by pass valve. Refer to Coolant Bypass Valve Replacement .
Is the repair complete? | Go to Step 5 | Go to Coolant Bypass Valve Replacement in Heating, Ventilation and Air Conditioning |
5 | Cycle the HVAC controls in order to verify proper operation. Did you find and correct the condition? | System OK | Go to Step 2 |