Removal Procedure
- Remove the HVAC module assembly (1). Refer to
HVAC Module Assembly Replacement
.
- Remove screws in order to separate the HVAC module assembly.
- Remove the screws from the air temperature actuator.
- Remove the air temperature actuator.
- Remove the screws from the mode actuator.
- Remove the mode actuator.
- Separate the HVAC module case halves.
- Remove the air temperature door (1) from the lower module half.
Installation Procedure
- Install the air temperature door (1) to the lower module half.
- Assemble the HVAC module case halves.
- Install the mode actuator.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the mode actuator.
Tighten
Tighten the screws to 1.9 N·m (17 lb in).
- Install the air temperature actuator.
- Install the screws to the air temperature actuator.
Tighten
Tighten the screws to 1.9 N·m (17 lb in).
- Install the screws in order to assemble the HVAC module.
Tighten
Tighten the screws to 1.9 N·m (17 lb in).
- Install the HVAC module assembly (1). Refer to
HVAC Module Assembly Replacement
.