The number below refers to the step number in the diagnostic table.
Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The auxiliary temperature cannot be adjusted, or the auxiliary heating is insufficient. | |||||||||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |||||||
2 |
Does the scan tool display DTC B0145, B0428, or B3531? | Go to Step 3 | |||||||
3 |
Does the scan tool indicate the Rear Temp. Select Sw. parameter change with each command? | Go to Step 4 | Go to Step 15 | ||||||
4 |
Does the auxiliary blower motor operate in any of the speed positions? | Go to Step 5 | |||||||
5 | Does the auxiliary blower motor operate at the desired speed? | Go to Step 6 | |||||||
6 |
Does the A/C compressor operate? | Go to Step 7 | |||||||
7 | Perform the Heating Performance Diagnostic. Refer to Heating Performance Diagnostic in Heating, Ventilation and Air Conditioning. Did you find and correct the condition? | Go to Step 18 | Go to Step 9 | ||||||
8 |
Does the Air Mix Door Actual parameter counts change? | Go to Step 9 | Go to Step 15 | ||||||
9 |
Does the inlet hose feel as warm as the outlet hose of the coolant bypass valve? | System OK | Go to Step 10 | ||||||
10 |
Does the test lamp illuminate with each command? | Go to Step 11 | |||||||
11 |
Does the test lamp illuminate with each command? | Go to Step 13 | Go to Step 12 | ||||||
12 | Test the coolant bypass solenoid control circuit of the coolant bypass valve for one of the following conditions:
Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 14 | ||||||
13 | Repair the ground circuit of the coolant bypass valve. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 18 | -- | ||||||
14 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 16 | ||||||
15 | Inspect for poor connections at the harness connector of the auxiliary HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 17 | ||||||
Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | Go to Step 18 | -- | |||||||
17 | Replace the auxiliary HVAC control module. Refer to Auxiliary Heater and Air Conditioning Control Module Replacement . Did you complete the replacement? | Go to Step 18 | -- | ||||||
18 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |