Removal Procedure
- Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement for the 4.2L engine or
Air Cleaner Assembly Replacement for the 4.8L, 5.3L, 6.0L, 6.2L, or 7.0L engine.
- Remove the bracket bolt securing the accumulator to the coolant recovery reservoir (1).
- Disconnect the electrical connector from the A/C pressure switch and reposition accumulator.
- Remove the coolant hoses from the coolant recovery reservoir and plug the hoses and the coolant recovery reservoir outlets with suitable plugs (2).
- Remove the nut and bolt securing the coolant recovery reservoir.
- Remove the coolant recovery reservoir.
Installation Procedure
- Install the coolant recovery reservoir.
Caution: Refer to Fastener Caution in the Preface section.
- Install the coolant recovery reservoir bolt.
Tighten
Tighten the bolt to 12 N·m (106 lb in).
- Install the coolant recovery reservoir nut.
Tighten
Tighten the nut to 10 N·m (89 lb in).
- Install the coolant hose to the coolant recovery reservoir (2).
- Install the accumulator to the coolant recovery reservoir and connect the electrical connector to the A/C low pressure switch.
- Secure the accumulator with the bracket and the bolt (1).
Tighten
Tighten the nut to 10 N·m (89 lb in).
- Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement for the 4.2L engine or
Air Cleaner Assembly Replacement for the 4.8L, 5.3L, 6.0L, 6.2L, or 7.0L engine.