Removal Procedure
- Remove the air cleaner outlet resonator. Refer to
Air Cleaner Outlet Resonator Replacement.
- Disconnect the electrical connector from the secondary air injection (AIR) reaction solenoid valve.
- Disconnect the AIR pump air outlet pipe from the AIR solenoid valve.
- Remove the nut (1) securing the transmission fluid level indicator tube (2) to the AIR solenoid valve.
- Remove the transmission fluid level indicator tube (2) from the AIR solenoid valve stud (3).
- Remove the 2 AIR solenoid valve studs (3).
- Remove the AIR solenoid valve (4) and the gasket (5) from the engine.
Installation Procedure
- Install the AIR solenoid valve (4) and the gasket (5) to the engine.
Caution: Refer to Fastener Caution in the Preface section.
- Install the 2 AIR solenoid valve studs (3).
Tighten
Tighten the studs to 25 N·m (18 lb ft).
- Install the transmission fluid level indicator tube (2) to the AIR solenoid valve stud (3).
- Install the nut (1) securing the transmission fluid level indicator tube (2) to the AIR solenoid valve.
Tighten
Tighten the nut to 10 N·m (89 lb in).
- Connect the AIR pump air outlet pipe to the AIR solenoid valve.
- Connect the electrical connector to the AIR solenoid valve.
- Install the air cleaner outlet resonator. Refer to
Air Cleaner Outlet Resonator Replacement.