• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Backup Lamp Switch B+ -- Manual Transmission | 1 | 1 | -- | -- |
Park/Neutral Position Switch B+ -- Automatic Transmission | 1 | 1 | -- | -- |
Backup Lamp Control | 1 | 1 | 1 | -- |
Backup Lamp - Left Ground | -- | 1 | -- | -- |
Backup Lamp - Right Ground | -- | 1 | -- | -- |
1. Backup Lamps Malfunction |
Battery voltage is applied to the backup lamp switch when the ignition switch is in the RUN or CRANK positions. When the transmission is placed in the REVERSE position, the backup lamp switch provides battery voltage to the backup lamps. The backup lamps are permanently grounded at G105. With both power and ground the backup lamps illuminate. Once the driver moves the gear selector out of the REVERSE position, the backup lamp switch contacts open and the backup lamps turn OFF.
Battery voltage is applied to the park/neutral position (PNP) switch when the ignition switch is in the RUN or CRANK positions. When the transmission is placed in the REVERSE position, the PNP switch provides battery voltage to the backup lamps. The backup lamps are permanently grounded at G105. With both power and ground the backup lamps illuminate. Once the driver moves the gear selector out of the REVERSE position, the PNP switch contacts open and the backup lamps turn OFF.
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the control circuit for a short to ground or an open/high resistance. |
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the backup lamps do not illuminate, test the control circuit terminal B for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the inoperative backup lamp. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the control circuit for a short to ground or an open/high resistance. |
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the backup lamps do not illuminate, test the control circuit terminal 10 for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the inoperative backup lamp. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.