Table 1: | Instrument Panel Cluster (IPC) |
Table 2: | Instrument Panel Cluster Control Module Output Control |
Scan Tool Parameter | System State | Expected Value | Definition |
---|---|---|---|
Operating Conditions: Ignition ON/Engine OFF/Seat Belt Buckled/High Beams Off/Park Brake Unapplied | |||
Battery Voltage | __ | 12.2 V (Varies) | The scan tool displays 0-19 volts. The voltage measured at the battery positive voltage circuit of the instrument panel cluster (IPC). |
Engine Coolant Temperature | __ | Varies | The scan tool displays 38°C-128°C (100°F-260°F). The displayed coolant temperature gage value in the IPC. This value may slightly differ from the monitored coolant temperature. |
Engine Speed | __ | 0 RPM | The scan tool displays 0-9999 RPM. The IPC monitors the engine speed signal circuit from the PCM. |
Fuel Level | __ | Varies | The scan tool displays 0-100%. The IPC calculates the amount of fuel remaining in the tank based on the input from the PCM. |
PRNDL State | __ | Varies | The scan tool displays Manual, Low, 2nd, 3rd, Drive, Neutral, Reverse, Park. The state of the PRNDL as commanded by the IPC. |
Trip Odometer | __ | Varies | The scan tool displays miles. The IPC calculates trip odometer information from the vehicle speed data received from the PCM. |
Trip Odometer | __ | Varies | The scan tool displays miles. The IPC calculates trip odometer information from the vehicle speed data received from the PCM. |
Trip Reset Switch | __ | Inactive | The scan tool displays Active or Inactive. The IPC monitors the control stem on the cluster. A closed switch is displayed as Active. |
Vehicle Speed | __ | 0 mph (0 km/h) | The scan tool displays 0-255 km/h (0-155 mph). The IPC monitors the vehicle speed signal circuit from the PCM |
Scan Tool Output Control | Description | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lamp Test | The IPC illuminates the following indicators when you select On:
| ||||||||||||||||
IPC Gages | The IPC drives all gages to the maximum physical position when you select On. The IPC drives all gages to the minimum physical position when you select Off. | ||||||||||||||||
PRNDL Display | An underscore illuminates under each indicator in the PRNDL display until commanded Off. |