• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
Roof Rail Module - Left High Control | B0068 | B0068 | B0062 | B0068 | B0061 |
Roof Rail Module - Left Low Control | B0068 | B0068 | B0062 | B0068 | B0061 |
The driver roof rail deployment loop consists of an inflatable restraint roof rail module - left and the roof rail module high and low circuits. A shorting bar used within the roof rail module connector shorts together both the roof rail module high and low circuits when the connector is disconnected. This will help to prevent unwanted deployment of the inflator module during servicing. During a side or frontal crash of sufficient force the inflatable restraint sensing and diagnostic module (SDM) will allow current to flow through the deployment loop in order to deploy the roof rail module. The SDM performs continuous diagnostic tests on the deployment loops to check for proper circuit continuity and for shorts to ground or voltage. If a malfunction is detected, a diagnostic trouble code (DTC) will be stored in memory.
Ignition voltage is between 9-16 volts.
DTC B0061 will set when the roof rail module-left deployment loop resistance is less than 1.3 ohms for 500 milliseconds.
DTC B0062 will set when one of the following conditions occurs:
• | Roof rail module-left high circuit is less than 2.4 volts and the roof rail module-left deployment loop is greater than 6 ohms for 500 milliseconds. |
• | Roof rail module-left deployment loop resistance is greater than 4.8 ohms for 500 milliseconds. |
DTC B0068 will set when one of the following conditions occur:
• | Roof rail module-left high or low circuits are shorted to voltage or shorted to ground for 500 milliseconds. |
• | Roof rail module-left high circuit is less than 2.4 volts and roof rail module-left deployment loop resistance is less than 6 ohms for 500 milliseconds. |
• | The SDM requests the instrument panel cluster (IPC) to illuminate the AIR BAG indicator. |
• | The SIR system is disabled and no deployments are allowed. |
• | The condition for setting the DTC no longer exists. |
• | A history DTC will clear once 100 malfunction-free ignition cycles have occurred. |
SIR System Description and Operation
Control Module References for scan tool information
• | EL 38715-125 Load Tool Adapter |
• | J 38715-A SIR Driver/Passenger Load Tool |
Important: Refer to SIR Service Precautions .
When removing the connectors, inspect for damage or corrosion. Damage or corrosion to the following requires repair or replacement of the affected component/connector:• | Inflatable restraint module |
• | SDM module |
• | Front end sensor wiring harness connector |
• | SDM wiring harness connector |
Important: The connector and connector position assurance (CPA) may seat independent of each other. Both the connector and CPA should seat with an audible and/or tactile click. The CPA isolates the shoring-bars within the connector allowing the deployment circuit to operate properly.
⇒ | If the above condition is not found, make the appropriate repair. |
⇒ | If the DTC is not set or is set as history, cycle the ignition OFF, disconnect the load tool and adapter, reconnect the harness connector at the left roof rail inflatable restraint module, and cycle the ignition ON. If the DTC resets after reconnecting the module, replace the left roof rail inflatable restraint module. |
⇒ | If not within the specified range, test the control circuit for a short to voltage. |
⇒ | If not within the specified range, test the control circuit for a short to voltage. |
⇒ | If not within the specified range, test the control circuit for a short to ground. |
⇒ | If not within the specified range, test the control circuit for a short to ground. |
⇒ | If not within the specified range, test the control circuit for an open/high resistance. |
⇒ | If not within the specified range, test the control circuit for an open/high resistance. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for SDM replacement, setup, and programming |