Tools Required
J 39400-A
Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Remove the right wiper arm linkage from the wiper arm pivot.
- Remove the nut (2) from the hose bracket.
- Remove the nut (3) from the hose bracket.
- Remove the evaporator outlet hose (1) from the evaporator.
- Remove the evaporator outlet hose O-ring seal.
- Remove the evaporator inlet hose (2) from the evaporator.
- Remove the evaporator inlet hose O-ring seal.
- Remove the primary evaporator core cover screws.
- Remove the primary evaporator core cover, foam insulator, and cover.
- Remove the secondary evaporator core cover screws.
- Remove the secondary evaporator core cover, the capture insert, and Styrofoam insulator.
- Remove the primary evaporator spacer.
- Remove the evaporator.
Installation Procedure
- If replacing the evaporator add refrigerant oil. Refer to
Refrigerant System Capacities
.
- Install the evaporator.
- Install the evaporator spacer.
Notice: Refer to Fastener Notice in the Preface section.
- Install the secondary evaporator core Styrofoam insulator, cover, tube capture insert, and screws.
Tighten
Tighten the screws to 2 N·m (17 lb in).
- Install the primary evaporator core cover and foam insulator.
- Install the primary evaporator core cover screws.
Tighten
Tighten the screws to 6 N·m (53 lb in).
- Install the new O-ring seals. Refer to
O-Ring Replacement
.
- Install the evaporator outlet hose (1) to the evaporator.
Tighten
Tighten the fitting to 32 N·m (24 lb ft).
- Install the evaporator inlet hose (2) to the evaporator.
Tighten
Tighten the fitting to 18 N·m (13 lb ft).
- Install the hose bracket and nut (2).
Tighten
Tighten the nut to 30 N·m (22 lb ft).
- Install the hose bracket and nut (3).
Tighten
Tighten the nut to 30 N·m (22 lb ft).
- Push the right wiper arm linkage carefully onto the wiper arm pivot and install the retaining screw.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the repaired or reinstalled components using the
J 39400-A
.