Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The condenser fan motor runs continuously. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Is the condenser fan motor running all the time? | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections |
3 | Remove the condenser motor relay. Did the condenser fan motor turn OFF? | Go to Step 5 | Go to Step 4 |
4 | Repair the short to B+ in the condenser fan motor supply voltage circuit. Refer to Wiring Repairs . Did you find and complete the repair? | Go to Step 13 | -- |
5 |
Does the A/C compressor operate? | Go to Step 6 | |
6 | Disconnect the A/C high pressure switch. Did the condenser fan motor turn OFF? | Go to Step 7 | Go to Step 8 |
7 |
Did you find and correct the condition? | Go to Step 13 | Go to Step 9 |
8 | Test the condenser relay control circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 10 |
9 | Inspect for poor connections at the harness connector of the A/C high pressure switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 11 |
10 | Inspect for poor connections at the harness connector of the condenser fan relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
11 | Replace the A/C high pressure switch. Refer to Air Conditioning (A/C) High Pressure Switch Replacement . Did you complete the repair? | Go to Step 13 | -- |
12 | Replace the condenser fan relay. Did you complete the repair? | Go to Step 13 | -- |
13 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |