Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Replacement
.
- Tilt the cab. Refer to
Cab Tilting
.
- Remove the drive belt. Refer to
Drive Belt Replacement
.
- Remove the generator mounting bolts.
- Remove the generator.
- Release the generator harness from the harness retainer.
- Disconnect the wiring connectors from the back of the generator.
Installation Procedure
- Connect the wiring connectors to the back of the generator.
Hold the hex-shaped base on the output terminal when you
tighten the nuts.
Tighten
Tighten the generator output terminal nut to 12 N·m (100 lb in).
- Connect the harness connector to the generator.
- Secure the generator harness to the harness retainer.
- Install the generator to the mounting bracket.
Notice: Refer to Fastener Notice in the Preface section.
- Tighten the generator mounting bolts.
Tighten
Tighten the mounting bolts to 88 N·m (65 lb ft).
- Install the drive belt. Refer to
Drive Belt Replacement
.
- Lower the cab. Refer to
Cab Tilting
.
- Connect the negative battery cable. Refer to
Battery Negative Cable Replacement
.