Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The blower motor is ON while the blower motor switch is in the OFF position. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Is the blower motor OFF? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Test each blower motor control circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 6 | Go to Step 4 |
4 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 6 | Go to Step 5 |
5 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |