System Performance Test for Isuzu Isuzu MD Steel Tilt (F Model) 1998
Tools Required
J 39500-B
- Park the vehicle inside a building or in a shaded area.
- Place the transmission in PARK or NEUTRAL.
- Open the hood.
- Secure the hood.
- Remove the low pressure hose cap.
- Remove the high pressure hose cap.
- Connect the low pressure
hose (1).
- Connect the high pressure hose (2).
- Start the engine.
- Stabilize the engine to a normal idling condition.
- Press the button in the ON position.
- Press the MAX/REC/RC button in the ON position.
- Adjust the blower speed to HI.
- Adjust the temperature control to full COLD.
- Carefully follow the manufacturer's instructions.
The normal temperature guideline for pressures readings is approximately
25--30°C (77--86°F).
The normal pressure guideline at ambient for the low pressure side is
approximately 127--265 kPa (18.5--38.4 psi).
The normal pressure guideline at ambient for the high pressure side
is approximately 1,373--1,765 kPa (199--255.9 psi).
Pressure
| Temperature
|
(kPa)
| (psi)
| (°C)
| (°F)
|
36
| 5.3
| -20
| -4.4
|
67
| 9.7
| -15
| 5
|
104
| 15
| -10
| 14
|
147
| 21
| -5
| 23
|
196
| 28
| 0
| 32
|
255
| 37
| 5
| 41
|
314
| 45
| 10
| 50
|
392
| 57
| 15
| 59
|
471
| 68
| 20
| 68
|
569
| 82
| 25
| 77
|
677
| 98
| 30
| 86
|
785
| 114
| 35
| 95
|
912
| 132
| 40
| 104
|
1059
| 154
| 45
| 113
|
1216
| 176
| 50
| 122
|