Coolant Level Sensor Replacement LG5
Removal Procedure
- Disconnect the electrical connector from the
probe.
Important: Catch any spilled coolant in a suitable container.
- Remove the low coolant probe from the surge tank (1).
Installation Procedure
- Install the coolant probe into the surge tank (1).
- Connect the electrical connector onto the probe.
- Fill the engine coolant to the proper level.