Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does a battery voltage exist? | -- | Go to Step 5 | Go to Step 2 |
2 | Inspect the condition of the indicator bulb. Is the indicator bulb in proper condition? | -- | Go to Step 4 | Go to Step 3 |
3 | Replace the indicator bulb. Is the battery still undercharged or overcharged? | -- | Go to Step 4 | System OK |
4 | Locate and repair the open in the BRN wire between the instrument cluster and the generator. Is the battery still undercharged or overcharged? | -- | Go to Step 5 | System OK |
5 | Connect a J 39200 from battery terminal 1 (RED) at the generator connector to chassis ground. Does the voltmeter read a battery voltage? | -- | Go to Step 7 | Go to Step 6 |
6 | Locate and repair the open in CKT 1 (RED) between the generator and the MaxiFuse® Block. Is the battery still undercharged or overcharged? | -- | Go to Step 7 | System OK |
7 |
Turn off all accessories. Does the voltmeter give a reading within the specified range? | 13-16 V | Go to Step 8 | Go to Step 9 |
8 | Perform a battery load test. Refer to Charging System Check . Is the battery still undercharged or overcharged? | -- | Go to Step 9 | System OK |
9 | Perform a generator bench test. Refer to Charging System Check Is the generator in need of repair or replacement? | -- | Go to Step 10 | Go to Step 11 |
10 | Repair or replace the generator. Refer to Generator Replacement . Is the battery still undercharged or overcharged? | -- | -- | System OK |
11 | Perform a battery load test. Refer to Charging System Check Is the battery still undercharged or overcharged? | -- | -- | System OK |