Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Definition: Auxiliary Relay Does Not Energize. | ||||
1 |
Does the test lamp light? | -- | Go to Step 2 | Go to Step 3 |
2 | Connect a test lamp from CKT 326 (BRN) at the Auxiliary Relay terminal 85 to CKT 327 (BLK) at the Auxiliary Relay terminal 86. Does the test lamp light? | -- | Go to Step 4 | Go to Step 5 |
3 | Locate and repair open in CKT 326 or CKT 371 (BRN) between the IP Fuse Block and the Auxiliary Relay. Is the repair complete? | -- | System OK | -- |
4 | Connect a test lamp from CKT 324 (ORN) at the Auxiliary Relay terminal 30 to ground. Does the test lamp light? | -- | Go to Step 6 | Go to Step 7 |
5 | Locate and repair open in CKT 21, CKT 327 or CKT 550 (BLK) between the Auxiliary Relay and ground G 105. Is the repair complete? | -- | System OK | -- |
6 | Connect a J 39200 between CKT 325 (PNK) at the Auxiliary Relay and CKT 320 (PNK) or CKT 339 (PNK) at the Body Builder Connector. Does the DMM indicate continuity? | -- | Go to Step 8 | Go to Step 9 |
7 | Locate and repair open in CKT 324 (ORN) between the IP Fuse Block and the Auxiliary Relay. Is the repair complete? | -- | System OK | -- |
8 | Replace the Auxiliary relay. Is the repair complete? | -- | System OK | -- |
9 | Locate and repair the open in CKT 320, CKT 325 or CKT 339 (PNK) between Auxiliary Relay and Body Builder Connectors. Is the repair complete? | -- | System OK | -- |