Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Battery Inspection/Test? | Go to Step 2 | Go to Battery Inspection/Test |
2 |
Is the charge indicator illuminated? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the charge indicator remain OFF? | Go to Step 4 | Go to Step 5 |
4 | Test the charge indicator control circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 7 | Go to Step 6 |
5 | Inspect for poor connections at the harness connector of the generator. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and repair the condition? | Go to Step 7 | Go to Charging System Test |
6 | Replace the battery lamp in the instrument cluster. Refer to Instrument Cluster Bulb Replacement in Lighting Systems. Did you complete the replacement? | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |