Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Suspension Controls Schematics | |||
1 | Did you review the system and circuit description and perform the necessary inspections? | Go to Step 2 | |
2 | Verify the fault is present. Does the system operate normally? | Go to Testing for Electrical Intermittents in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 7 | Go to Step 4 |
4 | Inspect the air suspension dump indicator control circuit for poor connections at the IP harness connector C5. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 5 |
5 | Check the air suspension dump indicator control circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 6 |
6 | Check the air suspension dump indicator ground circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | -- |
7 | Replace the IP cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gages, and Console. Did you complete the replacement? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |