An exhaust gas recirculation (EGR) system is used in order to lower oxides of nitrogen (NOx) emission levels caused by high combustion temperatures. The EGR accomplishes this by feeding small amounts of exhaust gases back into the combustion chamber. When the air/fuel mixture is diluted with the exhaust gases, combustion temperatures are reduced.
A linear EGR valve is used on this system. The linear EGR valve is designed in order to accurately supply exhaust gases to the engine without the use of intake manifold vacuum. The valve controls exhaust flow going into the intake manifold from the exhaust manifold through an orifice with a control module controlled pintle valve. The control module commands the EGR by applying a 12 volt duty cycle to the EGR valve. This can be monitored on a scan tool as desired EGR position.
The control module can monitor the pintle position with the EGR pintle position signal. This sensor uses a variable resistor with a 5 volt reference, a signal circuit, and a ground. The signal circuit monitors changes in voltage on the variable resistor as the pintle moves.
The VCM will set DTC P0404 if it detects enough difference between the desired EGR position and the actual EGR pintle position.
The ignition voltage is more than 5 volts.
The difference between the actual EGR position and the desired EGR position is more than 10 percent for more than 10 seconds.
• | The control module illuminates the malfunction indicator lamp (MIL) if a failure is detected during 2 consecutive key cycles. |
• | The control module sets the DTC and records the operating conditions at the time the diagnostic failed. The failure information is stored in the scan tool Freeze Frame/Failure Records. |
• | The control module turns OFF the MIL after 3 consecutive drive trips when the test has run and passed. |
• | A history DTC will clear if no fault conditions have been detected for 40 warm-up cycles. A warm-up cycle occurs when the coolant temperature has risen 22°C (40°F) from the startup coolant temperature and the engine coolant reaches a temperature that is more than 70°C (158°F) during the same ignition cycle. |
• | Use a scan tool in order to clear the DTCs. |
Excessive carbon deposits may cause restricted movement in the EGR pintle. This problem may be compounded by moisture freezing in the valve during cold weather . Use the scan tool in order to check for full range operation in the EGR system.
Check for excessive exhaust back pressure. Refer to Restricted Exhaust in Engine Exhaust.
An intermittent may be caused by any of the following conditions:
• | A poor connection |
• | Rubbed through wire insulation |
• | A broken wire inside the insulation |
Thoroughly inspect any circuitry that is suspected of causing the intermittent complaint. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
If a repair is necessary, refer to Wiring Repairs or Connector Repairs in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table.
This step will determine if the VCM can control the EGR valve.
Commanding the EGR valve to the specified values determines whether the VCM can control the EGR accurately. Production variations may not allow the EGR valve to be commanded to 100 percent.
There are certain circuits in the VCM C4 connector that could cause a short to voltage to the EGR valve control circuit that may disappear when the C4 connector is disconnected. Checking each individual circuit for a short to the EGR valve control circuit with a DMM will confirm if such a condition exists.
If the EGR valve 5 volt reference is shorted to voltage, the DMM will read battery voltage and additional DTCs may be set.
A problem which would not show up in probe-type testing may exist within the terminals. Be sure to check the terminals for being backed out, improperly-formed, or damaged.
A problem may exist within the terminals which would not show up in probe-type testing. Be sure to check the terminals for being backed out, improperly formed, or damaged.
Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | ||
Does the engine run rough or stall? | 50% | |||
Does the actual EGR position follow the commanded EGR position? | 0%, 20%, 50%, 70%, 100% | |||
4 | This DTC is intermittent. Are any additional DTCs stored? | -- | Go to applicable DTC | Go to Diagnostic Aids |
5 |
Is the test lamp ON? | 100% | ||
6 | Use a test lamp connected to B+ in order to probe the EGR valve ground circuit at the EGR valve connector. Is the test lamp ON? | -- | ||
7 |
Did you find a problem? | -- | ||
8 |
Did you find a problem? | -- | ||
9 |
Did you find a problem? | -- | ||
10 |
Is the test lamp ON? | -- | ||
11 |
Is the test lamp ON? | -- | ||
Are any circuits shorted to the EGR valve control circuit? | -- | |||
Use a DMM in order to measure the voltage between the 5-volt reference circuit at the EGR valve harness connector and a ground. Is the voltage more than the specified value? | 5.2 V | |||
14 | Use a DMM connected to a ground in order to measure the voltage on the EGR pintle position signal circuit at the EGR valve harness connector. Is the voltage at the specified value? | 0 V | ||
15 |
Did you find a problem? | -- | ||
16 | Use a test lamp connected to B+ in order to probe the EGR sensor ground circuit at the EGR valve harness connector. Is the test lamp ON? | -- | ||
17 | Repair the short to voltage in the EGR valve control circuit. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |
18 | Repair the short to the EGR valve control circuit. Refer to Wiring Repairs or Connector Repairs in Wiring Systems. Is the action complete | -- | -- | |
19 | Repair the short to voltage in the 5-volt reference circuit. Refer to Wiring Repairs in Wiring Systems. Is the action complete? | -- | -- | |
20 |
Did you find a problem? | -- | ||
Check for a faulty connection at the EGR valve. Refer to Connector Repairs in Wiring Systems Did you find a problem? | -- | |||
22 | Replace the EGR valve. Refer to Exhaust Gas Recirculation Valve Replacement . Is the action complete? | -- | -- | |
Check the VCM connectors for a faulty connection. Repair the connections as necessary. Refer to Connector Repairs in Wiring Systems. Did you find a problem? | -- | |||
24 |
Important: The replacement VCM must be programmed. Replace the VCM. Refer to VCM Replacement/Programming . Is the action complete? | -- | -- | |
25 |
Does the scan tool indicate that this diagnostic Passed? | -- | ||
26 | Does the scan tool display any additional undiagnosed DTCs? | -- | Go to applicable DTC | System OK |